by XINDA XINDA No Comments

Steam generators are used for sewage treatment

In recent years, the steam generators are widely used, especially sewage treatment. Sewage is produced every day, domestic sewage, industrial sewage, agricultural sewage, etc. These sewage contain a variety of heavy metal ions, waste acid, waste alkali and other harmful substances, so sewage treatment is related to our health and safety.

Steam generators use multi-effect evaporation process to treat sewage, after heating crystallization, all kinds of heavy metals or chemicals also precipitate, the sediment can be used as fertilizer for secondary use. The desalinated water can be further used to irrigate fields, trees and so on. In the process of sewage treatment, the steam generator reduces the production cost and improves the economic benefit.

steam generator

steam generator

by XINDA XINDA No Comments

What should I pay attention to when operating the steam boiler

When the steam boiler is running, it is necessary to observe the temperature and pressure of the boiler, the burning condition and make adjustments quickly. So how to adjust it? The Xinda boiler will explain it for you.

First of all, when the boiler is running, you often check the boiler steam pressure to ensure stable steam pressure. When steam pressure changes greatly, we have to find out the reason, contact the manufacturer to ask and solve it.

Then, we need to check the water level of the boiler to ensure that the water level is normal. When the water level is too low, the boiler is dried in the boiler due to severe water dehydration, which may damage the equipment. When the water level is too high, the steam has a large amount of water, which reduces the quality of the steam and affects the normal supply of vapor. In severe cases, the overheated device can accumulate dirt and damage the equipment. So when the water level of the boiler is too low or too high, we must give the water evenly.

In the end, after the ignition is successful, the burning status should be observed, the smoke exhaust temperature is inspected to ensure the steam generator operates safely.

by XINDA XINDA No Comments

How to deal with steam generator pressure is not up

Steam generators are a heating equipment that uses fuel (biomass, oil and gas, electricity, etc.) as combustion medium to heat water into steam. Steam generator has automatic control, low operating cost, high thermal efficiency and so on. Deeply loved by the majority of users, it has become one of the essential equipment of many enterprises. But when we use the steam generator, there will be some failures, such as pressure, burner can not start, can not out of steam. Today, Xinda boiler for you to explain, how to deal with steam generator pressure is not up?

1. Whether the pressure gauge is damaged: Check whether the pressure gauge is broken, because the pressure gauge is a real-time display of the boiler pressure. When the boiler is running, the pressure gauge always shows low pressure, you can calibrate it to see whether it can be used normally.

2. Whether the pump is damaged: Check whether the pump works normally. If it does not work, repair or replace it in time.

3. Check valve is blocked: when using the steam generator, it is easy to cause damage or blockage of the check valve, so that the water pump is blocked, and then the pressure can not go up.

In short, when the steam generator pressure does not go up, we should first check whether the valve of each instrument is normal or damaged, and whether it is in accordance with the correct operation method of the boiler. If the steam generator is still faulty, you can contact the manufacturer to see what the reason is.

by XINDA XINDA No Comments

Ship to Spain 2ton horizontal biomass steam boiler

Spain 2ton horizontal biomass steam boiler
Project location: Spain
Purchase equipment: DZL
Application: wineries

The project is horizontal biomass steam boiler used for winery. Customers find Xinda Boiler in Alibaba. According to the production volume of steamed wine required by the customer (per hour), 2ton/h boiler is sufficient for the customer. After comprehensive consideration, the customer finally chose the horizontal chain grate 2ton biomass steam boiler. The customer also purchased a water softener, which can effectively prevent boiler scaling, filter water impurities, prolong the service life of the boiler. Finally, the boiler is shipped to the customer’s location by sea from Shanghai port.

Xinda horizontal biomass steam boilers have microcomputer control system, continuous steam production, the whole distillation takes wine fast, is 2-3 times the traditional brewing. According to the customer’s feedback, after the use of Xinda boiler, the wine is very good.

 

by XINDA XINDA No Comments

Advantages and disadvantages of electric steam generators

Advantages of electric steam generators:

1. Environmental protection: The fuel used by the electric steam generator is electricity, which has the characteristics of clean environmental protection and no pollution, so as to achieve zero emission and zero pollution. It is the most environmentally friendly product in the steam generator at present.

2. High thermal efficiency: 3-5 minutes to produce steam, high thermal efficiency, up to 100%.

3. Easy to operate: automatic control, open with close, automatic water, easy to use.

4. Easy installation: small floor area, integrated factory, only need to connect the water source and power supply.

Disadvantages of electric steam generators:

High cost of use: in some areas, the price of electricity is relatively high, choose the cost of electric steam generator will be greatly increased. Therefore, when we buy the electric steam generator, we should combine their own situation to choose, so as to choose their own boiler products.

Xinda electric steam generator can produce steam quickly and has high thermal efficiency. It has a built-in automatic water pump, automatic water level, pressure control, can work continuously. All the equipment needs to be connected to a water source and a power source to generate steam. Vertical pipe structure, compact size, easy to move, install and use.

electric steam generator

by XINDA XINDA No Comments

Biomass steam generators are used in cleaning industries

Biomass steam generators are a new type energy saving and environmental protection heat energy equipment, suitable for various industries, is one of the necessary equipment in modern industry. In the cleaning industry, the application is more extensive. The following Xinda boiler to tell you in detail:

Cleaning industry: High temperature steam cleaning, oil cleaning, seamless pipeline cleaning, kitchen oil cleaning, airport stain cleaning, dryer cleaning, oil field equipment cleaning, aluminum alloy mold cleaning, industrial machine cleaning, engine cleaning, oil pipeline strainer cleaning, stainless steel plating parts cleaning, toughened glass hole sealing cleaning, food mold cleaning, food machinery cleaning, oven baking tray cleaning, transport vehicle cleaning , tank car cleaning, factory material box rack cleaning.

by XINDA XINDA No Comments

The reason why the electric steam generators heating tube is easy to damage

Electric heating tube is the core component of steam generator. Electric steam generator because of its compact size and convenient, fast steam (3-5 minutes) and other advantages, popular in various industries, become one of the indispensable products. Therefore, when we use the electric steam generator, we must follow the correct steps to operate it, otherwise it is easy to cause damage to the electric heating tube, so as to affect the normal production.

Heating tube is easy to damage several reasons

1. Water quality problem: if the water quality is not good, too many impurities, the heating pipe is easy to burn out when working. It is recommended to add water softener before water intake, so as to filter impurities in water and prolong the service life of steam generator.

2 Voltage problem: the common voltage is divided into two phase electricity and three phase electricity, voltage instability is easy to cause the heating tube power changes, thus burnt out.

3. Water level problem: steam generator water level is too low, electric heating tube has been dry burning, it is easy to damage the heating tube

4. Scale problem: when the steam generator is used for a period of time, the electric heating tube will be attached to a layer of roaring scale, which is easy to cause damage to the heating tube. So we need to clean the scale on the heating pipe regularly.

Xinda small automatic electric steam generators, use automatic alarm device, water shortage protection device, strictly prevent electric heat pipe dry burning, reliable performance. Stainless steel shell, easy to install, safe and reliable operation.

by XINDA XINDA No Comments

Steam generators play an important role in the food industry

Steam generator plays an important role in the food industry, such as distillery, meat factory, milk processing plant, beverage factory and other food industry in the production of multiple links can be used to steam generator.

The steam generator is mainly used in the distillation, extraction, sterilization, drying, curing and other processes in the process of food processing. It uses high temperature steam to cook, dry and sterilize food at high temperature.

Xinda steam generator is environmentally friendly steam generator, thermal efficiency up to 95%, 3-5 minutes can produce a lot of steam. Just pass the high temperature steam produced by the steam generator into the mechanical equipment, and use the high temperature and high pressure steam to bring heat food processing. Our products sold to the United States, Singapore, Germany and other more than 100 countries and regions.

by XINDA XINDA No Comments

Matters needing attention in biomass steam boiler ash removal

⒈ When the boiler is running, ash cleaning should be carried out once a day, open the boiler ash cleaning port, and remove the ash accumulation in the combustion chamber; Especially some large pieces of ash after burning, should be often timely removal, otherwise it will seriously affect the normal combustion of the boiler, and will increase the consumption of fuel.

2.After a week of operation of the boiler, the (waste heat recovery)ash removal tank shall be cleaned.

3. After one month of operation, all parts of the boiler should be checked. Instruments, valves, flanges and other places should be repaired if there is leakage, the water level probe should be removed and descaled, and the dirt inside the water level glass tube should also be cleaned, and check whether the smoke box is tightly sealed.

4. Boiler operation every 3-6 months, the boiler should be stopped for comprehensive inspection and maintenance. In addition to the above work, the following work should be carried out:

(1) Open each furnace door and cleaning mouth, check the smoke pipe, and remove the soot inside the pipe;

(2) Remove the scale and mud inside the drum, and rinse with clean water;

(3) Check the inside and outside of the boiler, such as the pressure part of the weld, there is no corrosion inside and outside the steel plate, if found to have serious defects should be repaired immediately, if the defect is not serious, can not be left to repair the next shutdown, if found suspicious, should be eliminated in time.

by XINDA XINDA No Comments

Blowdown of steam generator

Usually, raw water contains minerals, which will precipitate after entering the steam generator for vaporization, which may cause damage to the steam generator and cause safety accidents in serious cases. So must ensure the furnace water quality. When the quality of the furnace water exceeds the specified value of the water quality standard, it is necessary to carry out blowdown, generally a blowdown per class