1. Need to add water softener equipment before water, which can effectively reduce the generation of boiler scale. If there is no water softener, it should be descaled at least every month (the water quality is not up to standard, and a large amount of scale will cause damage to the boiler).
2. Regularly discharge the steam generator, so as not to accumulate too much pollution, block the pipeline, and cause damage to the steam generator.
3. The steam generator is cleaned regularly, the water is changed every week, and the various accessories (water level meter, electric tube, water tank, etc.) should also be cleaned and maintained regularly, so as to extend the service life of the boiler

.
4. The safety valve should be checked regularly to see if it fails, and manual pressure relief is discharged once a week.
5. The user is strictly prohibited to increase the pressure, if there is a problem should contact the manufacturer.
6. The steam generator should be maintained at the normal water level, and it is strictly prohibited to dry burn without water.
7. When the steam generator shows water shortage protection, water level gauge no water, boiler temperature is too high, should immediately cut off the power supply, contact the manufacturer for maintenance.